# Loads default set of integrations. Do not remove.
default_config:
# Load frontend themes from the themes folder
frontend:
themes: !include_dir_merge_named themes
automation: !include automations.yaml
script: !include scripts.yaml
scene: !include scenes.yaml
sensor:
- platform: serial
serial_port: /dev/ttyUSB_CH340
baudrate: 9600
template:
sensor:
- name: Temperature
unit_of_measurement: "°C"
state: "{{ states('sensor.serial_sensor').split()[2] | float(default=0) }}"
unique_id: temperature_sensor
- name: Humidity
unit_of_measurement: "%"
state: "{{ states('sensor.serial_sensor').split()[1] | float(default=0) }}"
unique_id: humidity_sensor
modbus:
- name: "SDM230 Smart Meter"
type: serial
baudrate: 9600
bytesize: 8
method: rtu
parity: N
port: /dev/ttyUSB_FT232
stopbits: 1
sensors:
- name: Voltage
unit_of_measurement: Volts
slave: 2
address: 0
input_type: input
data_type: float32
precision: 2
unique_id: "SDM230_Voltage"
- name: Current
unit_of_measurement: Amps
slave: 2
address: 6
input_type: input
data_type: float32
precision: 2
unique_id: "SDM230_Current"
- name: Active_Power
unit_of_measurement: Watts
slave: 2
address: 12
input_type: input
data_type: float32
precision: 2
unique_id: "SDM230_ActivePower"
- name: Apparent_Power
unit_of_measurement: Watts
slave: 2
address: 18
input_type: input
data_type: float32
precision: 2
unique_id: "SDM230_ApparentPower"
- name: Reactive_Power
unit_of_measurement: Watts
slave: 2
address: 24
input_type: input
data_type: float32
precision: 2
unique_id: "SDM230_ReactivePower"
- name: Power_Factor
slave: 2
address: 30
input_type: input
data_type: float32
precision: 2
unique_id: "SDM230_PowerFactor"
- name: Frequency
unit_of_measurement: Hz
slave: 2
address: 70
input_type: input
data_type: float32
precision: 2
unique_id: "SDM230_Frequency"
- name: Import_Active_Energy
unit_of_measurement: kWh
slave: 2
address: 72
input_type: input
data_type: float32
precision: 2
unique_id: "SDM230_ImportActiveEnergy"
- name: Export_Active_Energy
unit_of_measurement: kWh
slave: 2
address: 74
input_type: input
data_type: float32
precision: 2
unique_id: "SDM230_ExportActiveEnergy"
- name: Import_Reactive_Energy
unit_of_measurement: kVARh
slave: 2
address: 76
input_type: input
data_type: float32
precision: 2
unique_id: "SDM230_ImportReactiveEnergy"
- name: Export_Reactive_Energy
unit_of_measurement: kVARh
slave: 2
address: 78
input_type: input
data_type: float32
precision: 2
unique_id: "SDM230_ExportReactiveEnergy"
- name: Total_Active_Energy
unit_of_measurement: kWh
slave: 2
address: 342
input_type: input
data_type: float32
precision: 2
state_class: total_increasing
unique_id: "SDM230_TotalActiveEnergy"
- name: Total_Reactive_Energy
unit_of_measurement: kVARh
slave: 2
address: 344
input_type: input
data_type: float32
precision: 2
unique_id: "SDM230_TotalReactiveEnergy"
http:
# For extra security set this to only accept connections on localhost if NGINX is on the same machine
# Uncommenting this will mean that you can only reach Home Assistant using the proxy, not directly via IP from other clients.
# server_host: 127.0.0.1
use_x_forwarded_for: true
# You must set the trusted proxy IP address so that Home Assistant will properly accept connections
# Set this to your NGINX machine IP, or localhost if hosted on the same machine.
trusted_proxies: 192.168.10.41
# Modpoll for CJ meter
#./modpoll/x86_64-linux-gnu/modpoll -h
#modpoll 3.10 - FieldTalk(tm) Modbus(R) Master Simulator
#Copyright (c) 2002-2021 proconX Pty Ltd
#Visit https://www.modbusdriver.com for Modbus libraries and tools.
#
#Usage: modpoll [OPTIONS] SERIALPORT|HOST [WRITEVALUES...]
#Arguments:
#SERIALPORT Serial port when using Modbus ASCII or Modbus RTU protocol
# COM1, COM2 ... on Windows
# /dev/ttyS0, /dev/ttyS1 ... on Linux
#HOST Host name or dotted IP address when using MDBUS/TCP protocol
#WRITEVALUES List of values to be written. If none specified (default) modpoll reads data.
#General options:
#-m ascii Modbus ASCII protocol
#-m rtu Modbus RTU protocol (default if SERIALPORT contains a /)
#-m tcp MODBUS/TCP protocol (default otherwise)
#-m udp MODBUS UDP
#-m enc Encapsulated Modbus RTU over TCP
#-a # Slave address (1-247 for serial, 0-255 for TCP, 1 is default)
#-r # Start reference (1-65536, 100 is default)
#-c # Number of values to read (1-125, 1 is default), optional for writing (use -c 1 to force FC5 or FC6)
#-t 0 Discrete output (coil) data type
#-t 1 Discrete input data type
#-t 3 16-bit input register data type
#-t 3:hex 16-bit input register data type with hex display
#-t 3:int 32-bit integer data type in input register table
#-t 3:mod 32-bit module 10000 data type in input register table
#-t 3:float 32-bit float data type in input register table
#-t 4 16-bit output (holding) register data type (default)
#-t 4:hex 16-bit output (holding) register data type with hex display
#-t 4:int 32-bit integer data type in output (holding) register table
#-t 4:mod 32-bit module 10000 type in output (holding) register table
#-t 4:float 32-bit float data type in output (holding) register table
#-i Slave operates on big-endian 32-bit integers
#-f Slave operates on big-endian 32-bit floats
#-e Use Daniel/Enron single register 32-bit mode (implies -i and -f)
#-0 First reference is 0 (PDU addressing) instead 1
#-1 Poll only once only, otherwise every poll rate interval
#-l # Poll rate in ms, (1000 is default)
#-o # Time-out in seconds (0.01 - 10.0, 1.0 s is default)
#Options for MODBUS/TCP, UDP and RTU over TCP:
#-p # IP protocol port number (502 is default)
#Options for Modbus ASCII and Modbus RTU:
#-b # Baudrate (e.g. 9600, 19200, ...) (19200 is default)
#-d # Databits (7 or 8 for ASCII protocol, 8 for RTU)
#-s # Stopbits (1 or 2, 1 is default)
#-p none No parity
#-p even Even parity (default)
#-p odd Odd parity
#-4 # RS-485 mode, RTS on while transmitting and another # ms after
# ./modpoll -c 80 -b 9600 -a 1 -1 -p none -t 3 /dev/ttyUSB0
# modpoll 3.10 - FieldTalk(tm) Modbus(R) Master Simulator
# Copyright (c) 2002-2021 proconX Pty Ltd
# Visit https://www.modbusdriver.com for Modbus libraries and tools.
#
#Protocol configuration: Modbus RTU, FC4
#Slave configuration...: address = 1, start reference = 1, count = 80
#Communication.........: /dev/ttyUSB0, 9600, 8, 1, none, t/o 1.00 s, poll rate 1000 ms
#Data type.............: 16-bit register, input register table
#-- Polling slave...
#[1]: 8888
#[2]: 256
#[3]: 0
#[4]: 1
#[5]: 16
#[6]: -30846
#[7]: 5000
#[8]: 3000
#[9]: -31868
#[10]: 3000
#[11]: 6000
#[12]: 257
#[13]: 257
#[14]: 257
#[15]: 0
#[16]: 0
#[17]: 0
#[18]: 0
#[19]: 0
#[20]: 0
#[21]: 500
#[22]: 30
#[23]: -30844
#[24]: 6000
#[25]: 6000
#[26]: 257
#[27]: 0
#[28]: 0
#[29]: 0
#[30]: 0
#[31]: 0
#[32]: 0
#[33]: 0
#[34]: 0
#[35]: 0
#[36]: 769
#[37]: 1135
#[38]: 2288
#[39]: 0
#[40]: 0
#[41]: 2288
#[42]: 0
#[43]: 2288
#[44]: 5216
#[45]: 0
#[46]: 0
#[47]: 865
#[48]: 0
#[49]: 0
#[50]: 865
#[51]: 587
#[52]: 0
#[53]: 0
#[54]: 587
#[55]: 827
#[56]: 999
#[57]: 999
#[58]: 827
#[59]: 1046
#[60]: 0
#[61]: 0
#[62]: 1046
#[63]: 4995
#[64]: 14
#[65]: -25104
#[66]: 0
#[67]: 0
#[68]: 9
#[69]: -13187
#[70]: 0
#[71]: 0
#[72]: 19305
#[73]: -4744
#[74]: 0
#[75]: 0
#[76]: 19228
#[77]: -11734
#[78]: 0
#[79]: 0
#[80]: 0